Tripp-Lite SU6000RTFMB no break tripp lite series ups smartonline de 6000va 5400 w 120/208v doble conversión en línea con transformador reductor y derivación mantenimiento - tomas 5-20r/l6-20r/l6-30r,
Precio especial $114,532.00 IVA incluido + Envio $150 MXN
Antes $132,857.00
Disponible 1 Pzas
Antes $132,857.00
Disponible 1 Pzas
sku: SU6000RTFMB
pub
MX0000106996
Eaton Tripp Lite Series 6000VA 5400W 120/208V Online Double-Conversion UPS with Stepdown Transformer and Maintenance Bypass
SU6000RTFMB
Eaton Tripp Lite Series 6000VA 5400W 120/208V Online Double-Conversion UPS with Stepdown Transformer and Maintenance Bypass
- UPS (rack-mountable)
- AC 120-208 V
- 5400 Watt
- 6000 VA
- 1-phase
- valve regulated lead-acid (VRLA)
- output connectors: 18
- 6U
- for P/N: BP180RT
6kVA/5.4kW/120V/208V Battery Backup for IT Installations and Edge Networks
This SmartOnline rack-mount online double-conversion UPS system provides uninterrupted battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage valuable IT equipment or destroy data. An included stepdown transformer converts your UPS, utility or generator s 208V high-voltage input to 120V low-voltage output to allow connection of a wider range of components.
Expandable Internal Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable valve regulated lead acid (VRLA) battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Automatic restart after power outages reduces costly on-site visits. You can also connect up to four extended battery modules (BP180RT, sold separately) for hours of extended runtime.
Included Bypass Switch Isolates UPS from Connected Loads for Maintenance
The manual bypass lets you remove the UPS for maintenance without disrupting power to the connected load. The bypass reroutes utility power to keep essential equipment operational while you re servicing or replacing the UPS system.
Pre-Installed Network Interface Offers 24/7 Remote Access
The WEBCARDLXE network interface turns the SU6000RTFMB into a managed device on your network. It enables full remote configuration and SNMP-based UPS management, including load shedding, safe shutdowns and automated alerts. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment without an on-site visit. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA Outlets Protect Your Connected Components
One L6-30R, two L6-20R and 18 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The SU6000RTFMB also supports hardwired output.
Intuitive LCD Interface Keeps You Informed at a Glance
The menu-driven LCD provides control settings and critical information to help diagnose any issues, including alarm and fault notifications. The interface rotates to accommodate both rack-mount and tower configurations, and it tilts up to 45 degrees for more comfortable viewing.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a serial-enabled device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO connectors permit emergency shutdown or remote restart of all connected equipment.
Versatile Installation Options
You can mount the SU6000RTFMB in 6U of space in an EIA-standard 19-inch rack using the included 4-post rail kit or an optional 2-post rail kit (RK2PC, sold separately, one required for each UPS, EBM or transformer). You can also adapt it for tower installation using the included support stands. The 10-foot power cord with NEMA L6-30P plug connects to a compatible AC outlet. A cable gland is included for alternate hardwire input.
This SmartOnline rack-mount online double-conversion UPS system provides uninterrupted battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage valuable IT equipment or destroy data. An included stepdown transformer converts your UPS, utility or generator s 208V high-voltage input to 120V low-voltage output to allow connection of a wider range of components.
Expandable Internal Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable valve regulated lead acid (VRLA) battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Automatic restart after power outages reduces costly on-site visits. You can also connect up to four extended battery modules (BP180RT, sold separately) for hours of extended runtime.
Included Bypass Switch Isolates UPS from Connected Loads for Maintenance
The manual bypass lets you remove the UPS for maintenance without disrupting power to the connected load. The bypass reroutes utility power to keep essential equipment operational while you re servicing or replacing the UPS system.
Pre-Installed Network Interface Offers 24/7 Remote Access
The WEBCARDLXE network interface turns the SU6000RTFMB into a managed device on your network. It enables full remote configuration and SNMP-based UPS management, including load shedding, safe shutdowns and automated alerts. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment without an on-site visit. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA Outlets Protect Your Connected Components
One L6-30R, two L6-20R and 18 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The SU6000RTFMB also supports hardwired output.
Intuitive LCD Interface Keeps You Informed at a Glance
The menu-driven LCD provides control settings and critical information to help diagnose any issues, including alarm and fault notifications. The interface rotates to accommodate both rack-mount and tower configurations, and it tilts up to 45 degrees for more comfortable viewing.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a serial-enabled device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO connectors permit emergency shutdown or remote restart of all connected equipment.
Versatile Installation Options
You can mount the SU6000RTFMB in 6U of space in an EIA-standard 19-inch rack using the included 4-post rail kit or an optional 2-post rail kit (RK2PC, sold separately, one required for each UPS, EBM or transformer). You can also adapt it for tower installation using the included support stands. The 10-foot power cord with NEMA L6-30P plug connects to a compatible AC outlet. A cable gland is included for alternate hardwire input.
Key Points
- Provides sine wave output, complete battery backup and power protection for mission-critical IT installations, edge networks and other advanced network applications
- Keeps equipment running during outages to allow time for file saves and safe shutdown
- Pre-installed WEBCARDLXE network card enables full remote access and control
- Stepdown transformer converts 208V input into 120V output for low-voltage equipment
- Included bypass switch allows uninterrupted operation during UPS maintenance
- This product is covered by a 2-year limited warranty
Product Features
- Durable battery technology
- Advanced power delivery
- Comprehensive connectivity options
- User-friendly monitoring
- Environmentally compliant
Specifications | |
---|---|
Dimensions & Weight / Depth | 86.36 cm |
Dimensions & Weight / Height | 25.91 cm |
Dimensions & Weight / Weight | 93.49 kg |
Dimensions & Weight / Width | 43.94 cm |
General / Subcategory | UPS |
Header / Brand | Eaton |
Miscellaneous / Product Color | Black |
Networking / Remote Management Interface |
|
Packaged Quantity | 1 |
Power Device / Form Factor | Rack-mountable |
Power Device / Output Connector Qty | 18 |
Power Device / Power Capacity (VA) | 6000 VA |
Power Device / UPS Technology | On-line |
Power Device / Voltage Required | AC 120-208 V |
Product Type | UPS |
Service & Support / Type | 2-year warranty |
Battery | |
Features | Sealed |
Quantity | 4 |
Technology | Valve regulated lead-acid (VRLA) |
Type | Expandable |
Voltage Provided | AC 120/208 V |
Compatibility Information | |
Designed For | P/N: BP180RT |
Dimensions & Weight | |
Depth | 86.36 cm |
Height | 25.91 cm |
Weight | 93.49 kg |
Width | 43.94 cm |
Environmental Parameters | |
Humidity Range Operating | 0 - 95% RH (non-condensing) |
Max Operating Temperature | 40 °C |
Min Operating Temperature | 0 °C |
General | |
Device Type | UPS - rack-mountable |
Height (Rack Units) | 6U |
Manufacturer Warranty | |
Service & Support | Limited warranty - 2 years |
Miscellaneous | |
Cables Included | Power cable (NEMA L6-30P) 3.05 m |
Compliant Standards | NOM, cUL Listed, IEC/EN 62040-2, RoHS, Energy Star, FCC Class A certified, FCC |
Equipment Protection Value | 250000 US Dollars |
Features | Surge protection, double conversion, internal bypass, LCD display, VRLA battery support, audible alarm, fault alarm, low battery alarm, overload alarm, LED indicators, integrated network management, cold-start function, Remote Emergency Power Off (REPO), energy saving green topology |
Included Accessories | SUPDMBP6K maintenance bypass, network interface card (WEBCARDLXE), USB cable, hardwire connection cable gland, tower support stands, maintenance bypass mounting hardware, UPS and transformer rack-mounting hardware (2x 9RK), step-down transformer |
Rack Mounting Kit | Included |
Power Device | |
Efficiency | 93% |
Frequency Provided | 50/60 Hz |
Frequency Required | 50/60 Hz |
Input Connectors | 1 x power NEMA L6-30P, hardwire |
Input Voltage | AC 120-208 V |
Input Wiring | 1-phase |
Max Electric Current | 24.8 A |
Output Voltage | AC 120-208 V 50/60 Hz |
Output Waveform | Sinewave |
Power Capacity | 5400 Watt / 6000 VA |
Power Factor (PF) | 0.9 |
Power Output Connectors Details |
|
UPS Technology | On-line |
Software / System Requirements | |
Software Included | TrippLite PowerAlert |
Sustainability Information | |
ENERGY STAR | Yes |
Marca | Otros |
---|---|
MPN: | SU6000RTFMB |