Cyberpower OLS3000RT2UA no break ups tipo torre 3000va / 2700w
Precio especial $20,794.00 IVA incluido + Envio $150 MXN
Antes $24,121.00
Disponible 105 Pzas
Antes $24,121.00
Disponible 105 Pzas
sku: OLS3000RT2Ua
pub
MX0000089569
| GENERAL | |
|---|---|
| Phase | Single Phase |
| Form Factor | Rackmount, Tower |
| UPS Topology | Online Double Conversion |
| Energy Saving Technology | Online ECO Mode Efficiency > 95% |
| Active PFC Compatibility | Yes |
| INPUT | |
|---|---|
| Generator Compatibility | Yes |
| Nominal Input Voltage ( Vac ) | 230 ± 10% |
| Input Voltage Range ( Vac ) | 190 ~ 300 |
| Adjustable Voltage Range ( Vac ) |
0~30% Load for 80 ~ 300 Vac 0~60% Load for 140 ~ 300 Vac 0~80% Load for 160 ~ 300 Vac 0~100% Load for 190 ~ 300 Vac |
| Input Frequency ( Hz ) |
50 +- 10 60 +- 10 |
| Input Frequency Detection | Auto-sensing |
| Rated Input Current ( A ) | 13 |
| Input Power Factor | 0.99 |
| Input Connector Type | IEC C20 |
| Detachable Power Cord Plug Type | Schuko x 1 |
| Power Cord Length (ft.) | 5 |
| Power Cord Length (m.) | 1.5 |
| OUTPUT | |
|---|---|
| Capacity (VA) | 3000 |
| Capacity (Watts) | 2700 |
| On Battery Waveform | Pure Sine Wave |
| On Battery Voltage(s) ( Vac ) |
208 +- 1% 220 +- 1% 230 +- 1% 240 +- 1% |
| Output Voltage Setting | Configurable |
| On Battery Frequency ( Hz ) |
50 +- 0.5% 60 +- 0.5% |
| Output Frequency Setting | Configurable |
| Power Factor | 0.9 |
| ECO Mode Voltage Tolerance | +- 15 % |
| Overload Protection | Internal Current Limiting, Circuit Breaker, Fuse |
| Overload Protection (Line Mode) | 110~120% Load for 1 min, >120% Load Immediately |
| Overload Protection (Battery Mode) | 110~120% Load for 10 sec, >120% Load Immediately |
| Overload Protection (Bypass Mode) | >130% Load Immediately |
| Crest Factor | 3 : 1 |
| Harmonic Distortion (Linear Load) | THD<3% |
| Harmonic Distortion (Non-linear Load) | THD<5% |
| Internal Bypass | Automatic Bypass, Manual Bypass |
| Outlet(s) - Total | 10 |
| Outlet Type |
IEC C19 x 2 IEC C13 x 8 |
| Outlet(s) - Battery & Surge Protected | 10 |
| Outlet(s) - Critical Load (CL) | 6 |
| Outlet(s) - Non-Critical Load (NCL) | 4 |
| Typical Transfer Time ( ms ) | 0 |
| BATTERY | |
|---|---|
| Runtime at Half Load ( min ) | 13.8 |
| Runtime at Full Load ( min ) | 4 |
| Typical Recharge Time ( Hours ) | 4 |
| Maximum Charging Current ( A ) | 1.5 |
| Start On Battery | Yes |
| Smart Battery Management (SBM) | Yes |
| User-replaceable | Yes - Qualified Personnel Only |
| Battery Type | Sealed Lead-acid |
| Replacement Battery Pack (RBP) | RBP0158 |
| Replacement Battery Pack (RBP) Quantity ( pcs ) | 1 |
| Battery Quantity (Each RBP) ( pcs ) | 6 |
| Battery Voltage (Each RBP) ( V ) | 72 |
| Compatible Extended Battery Module (EBM) | BPSE72V40ART2U |
| Extended Battery Module Auto-detection | Yes |
| Max. EBM Quantity ( pcs ) | 3 |
| SURGE PROTECTION & FILTERING | |
|---|---|
| Surge Suppression ( Joules ) | 388 |
| EMI/RFI Filtration | Yes |
| Phone/Network Protection RJ11/RJ45 (Combo) | 1-in, 1-out |
| MANAGEMENT & COMMUNICATIONS | |
|---|---|
| LCD Panel | Yes |
| LCD Types | Color LCD |
| LCD Information Display | Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log |
| LCD Setting & Control | Mode Setting, Alarm Setting, Input & Output, Battery Setting |
| HID Compliant USB Port(s) | 1 |
| Dry Contact (with Relay) | Yes |
| Emergency Power Off (EPO) Port | Yes |
| Audible Alarms | Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery |
| Management Cable ( pcs ) | Power Cord x2, USB Cable x1 |
| Power Management Software | PowerPanel Business (Recommended) |
| SNMP/HTTP Remote Monitoring | Yes - with optional RMCARD205 |
| PHYSICAL | |
|---|---|
| Enclosure Construction | Metal |
| Color | Black |
| Rackmount Rail | Yes |
| Rackmount Ears | Yes |
| PHYSICAL SIZE - UPS MODULE | |
|---|---|
| Dimensions (WxHxD) (in.) | 17.24 x 3.46 x 24.2 |
| Dimensions (WxHxD) (mm.) | 438 x 88 x 610 |
| Weight (lbs.) | 58.8 |
| Weight (kg.) | 26.7 |
| Installed Rack Height ( U ) | 2 |
| SHIPPING DIMENSIONS | |
|---|---|
| Dimensions (WxHxD) (in.) | 21.3 x 9 x 28.7 |
| Dimensions (WxHxD) (mm.) | 540 x 230 x 730 |
| Weight (lbs.) | 69.1 |
| Weight (kg.) | 31.3 |
| ENVIRONMENTAL | |
|---|---|
| Operating Temperature (°F) | 32 ~ 104 |
| Operating Temperature (°C) | 0 ~ 40 |
| Operating Relative Humidity (Non-condensing) ( % ) | 20 ~ 90 |
| Operating Elevation ( feet/meters ) | 0-4,921 feet (0-1,500 meters) |
| Storage Temperature (°F) | -4 ~ 122 |
| Storage Temperature (°C) | -20 ~ 50 |
| Storage Relative Humidity (Non-condensing) ( % ) | 10 ~ 90 |
| Storage Elevation ( feet/meters ) | 0-4,921 feet (0-1,500 meters) |
| Online Thermal Dissipation ( BTU/hr ) | 911 |
| Variable Speed Fans | 20 steps automatically |
| CERTIFICATIONS | |
|---|---|
| Certifications | CE, EAC |
| RoHS | Yes |
| WARRANTY | |
|---|---|
| Product Warranty Period (Year) | 2 |
| Battery Warranty Period (Year) | 2 |
| Marca | Cyberpower |
|---|---|
| MPN: | OLS3000RT2Ua |

The information below is required for social login
Iniciar Sesión
Crear una nueva cuenta