Tripp Lite SU5KRT3UHVMB ups en línea 208v240v 5000va5000w pdu derivación factor potencia uno entrada instalación eléctrica

Precio especial $109,283.00 IVA incluido + Envio $150 MXN
Antes $126,768.00
Disponible 0 Pzas
Agotado
pub
MX0000088711
Precios sujetos a cambios sin previo aviso
Pagos 100% seguros
Entrega Aprox.
Envio Nacional | Condicion: Nuevo

Datos español

Corriente especificada de entrada (Carga Máxima): Instalación eléctrica permanente de entrada de CA: 27A (200V), 25.6A (208V), 22.2A (240V) máximo; Con entrada NEMA L6-30P incluida: 24A (200V / 208V / 240V) máximo; Corriente máxima de arranque: 100A
Voltaje(s) Nominal(es) de Entrada Soportado(s): 200V CA; 208V CA; 240V CA
Descripción del Voltaje Nominal de Entrada: 208V predeterminado de fábrica
Tipo de conexión de entrada del UPS: Instalación Eléctrica Permanente; L6-30P
Fase de Entrada: Monofásico
Frecuencia de Entrada: 50Hz / 60Hz
Factor de Potencia (Entrada): 0.98 mínimo (a plena carga, voltaje nominal de entrada)
THDi: <8% a plena carga; <10% a media carga
Capacidad de Salida en Volts Amperes (VA): 5000
Capacidad de Salida (Watts): 5000
Capacidad de salida (kW): 5
Factor de Potencia: 1.0
Factor de Cresta: 3:1 máximo
Compatibilidad de Frecuencia: 50Hz / 60Hz
Forma de Onda de CA de Salida (Modo de CA): Onda Sinusoidal Pura
Voltaje(s) Nominal(es) de Salida Soportado(s): 200V; 208V; 220V; 230V; 240V
Tomacorrientes: Instalación Eléctrica Permanente; (2) L6-20R; (2) L6-30R
Tipo de Batería: Plomo Ácido Regulada por Válvula [VRLA]
Pantalla LCD del Panel Frontal: La pantalla LCD seleccionable con botones Escape, RePag, AvPag, Intro y Encendido habilita las opciones de control y monitoreo detallado del UPS; el panel LED / LCD gira para visualizarlo en formatos de Rack o Torre (consulte el manual)
Factor de Forma Primario: Factor de Forma Primario
Altura del Rack: 3U
Dimensiones: 29.46 cm x 25.4 cm x 13.03 cm
Peso: 54.98 kg


Datos en ingles

 

Tripp Lite UPS Smart Online 5kVA 5kW 208/240V Unity Power Factor ByPass PDU 3URM - 3U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC Output - 2 x NEMA L6-30R, 2 x NEMA L6-20R, Hardwired - TAA Compliant

Protects Mission-Critical Rack-Mounted Equipment against Damage, Downtime and Data Loss

Tripp Lite s SU5KRT3UHVMB Unity Power Factor UPS system with Maintenance Bypass Switch and Detachable PDU protects connected equipment against damage, downtime and data loss due to power outages, voltage fluctuations and transient surges. Unity Power Factor design enables full 5000VA / 5000W output capacity when used with hardwire 208/240V input power (output de-rates to 4800W at 208V with included L6-30P cord option). In double-conversion mode, this UPS system maintains perfect output by continuously converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with ±1% voltage regulation and zero transfer time between online and battery modes. Featuring true on-line, double-conversion operation, Tripp Lite s SmartOnline® SU5KRT3UHVMB provides the highest level of UPS power protection for critical server, network and telecom equipment.

High Availability Configuration Offers Reliable, Expandable Battery Backup

Included Maintenance Bypass Switch is mounted on a detachable Bypass PDU that securely mounts to the rear-rails of a 4 post rack enclosure and remains safely in-place powering your equipment during UPS maintenance. The UPS connects to the Bypass PDU using a sophisticated blind-mate connector set with self-aligning guide-pins to ensure safe and reliable whole-UPS replacement with zero downtime for connected equipment. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The internal battery set provides 14 minutes of support at half load and 5 minutes at full load. During normal operation, incoming utility power keeps the battery fully charged so backup power will be available when needed. Advanced temperature-controlled battery charge management system provides efficient recharge and enhanced battery lifespan. For mission critical applications demanding continuous uptime, the 5kVA UPS can provide expandable runtime with optional BP192V12RT3US external battery pack (sold separately). Battery-independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries.

Economy Mode Helps the Environment and Your Cash Flow

Operates with >98% full-load efficiency in optional economy mode significantly reducing BTU heat output and operating energy costs.

Intuitive Front-Panel Interface offers Convenient Monitoring

Front-panel LEDs indicate line power, AC output, On-battery mode, and Fault conditions. The LCD readout with scroll controls supports visual monitoring of a variety of control options to support advanced UPS settings and configurations. The panel rotates for comfortable viewing in rack-mount or tower configuration.

Pre-installed WEBCARDLXMINI Network Interface Offers 24/7 Access

Pre-installed Java-free HTML5-based WEBCARDLXMINI interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. Advanced Communications Ports USB and DB9 ports with included cabling enable data-saving unattended shutdown of connected systems when used with Tripp Lite s free downloadable PowerAlert® software. Capabilities include detailed monitoring of load levels, self-test data and utility power conditions.

 
Features
  • Unity (1.0) power factor equalizes VA and wattage to safely support more equipment
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • Detachable PDU with maintenance bypass switch allows convenient hot-swapping
  • Pre-installed WEBCARDLXMINI network interface supports Auto Probe feature
  • ENERGY STAR-certified to save electricity, lower costs and protect the environment
  • 2-year limited warranty
  • $250,000 Ultimate Lifetime Insurance

Technical Specs

 
Controls/Indicators
Status Indicators

Front Panel LCD Display:

      • Selectable LCD display with Escape
      • Page Up
      • Page Down
      • Enter and Power buttons enable UPS control
      • Detailed monitoring options
      • LED/LCD panel rotates for viewing in rack/tower formats

4 Front-Panel LEDs:

    • AC Input
    • AC Output
    • Battery Mode
    • Fault Conditions
Management
Network Management SNMP/Telnet/SSH
Alarm UPS Power Condition
Interfaces/Ports
Serial Port Yes
EPO Port Yes
USB (HID Compliant) Port Yes
Environmental Conditions
Sound Emission 67 dB
Thermal Dissipation 307.72 W
Maximum Operating Temperature 104°F (40°C)
Maximum Operating Elevation 6562 ft
Physical Characteristics
Weight (Approximate) 121.21 lb
Form Factor Rack/Tower
Rack Height 3U
Height 5.2'
Width 17.5'
Depth 35.5'
Miscellaneous
Package Contents
  • SmartOnline SU5KRT3UHVMB 5kVA Rack/Tower UPS
  • Pre-installed WEBCARDLXMINI Network Management Card
  • 2 x Hardwire Strain Reliefs
  • USB Cable
  • RS-232 Cable
  • Rack-mounting Hardware
  • Owner s Manual
  • Detachable Bypass PDU
  • NEMA L6-30P Power Cable
Software Included PowerAlert
Country of Origin Taiwan
Environmentally Friendly Yes
Environmental Certification RoHS
TAA Compliant Yes
Energy Star Yes
Technical Information
Application/Usage Telecommunication
Server
Mission Critical Equipment
Data Center
Computer Room
Network Equipment
Overload Protection Yes
Plug/Connector Type NEMA L6-30P
Hardwired
Phase Single Phase
Receptacle Type Hardwired
NEMA L6-20R
NEMA L6-30R
EMI/RFI Noise Filter Yes
Transfer Time 0 ns
Receptacle Detail 2 x NEMA L6-30R
2 x NEMA L6-20R
Battery Information
Battery Chemistry Lead Acid
Hot Swappable Yes
Backup/Run Time (Half Load) 14 Minute
Backup/Run Time (Full Load) 5 Minute
Battery Characteristics Valve-regulated
Replaceable Battery Yes
DC System Voltage 192 V DC
Typical Battery Recharge Time 3 Hour
General Information
Product Type Double Conversion Online UPS
Manufacturer Part Number SU5KRT3UHVMB
Manufacturer Website Address http://www.tripplite.com
Manufacturer Tripp Lite by Eaton
Product Model SU5KRT3UHVMB
Product Name SmartOnline SU5KRT3UHVMB 5kVA Rack/Tower UPS
Product Line SmartOnline
Brand Name Tripp Lite
Power Description
Input Voltage 230 V AC
230 V AC
Output Voltage 220 V AC
208 V AC
200 V AC
240 V AC
230 V AC
220 V AC
240 V AC
230 V AC
200 V AC
208 V AC
Surge Energy Rating 1680 J
Waveform Type Pure Sine Wave
Output Frequency 60 Hz
60 Hz
Input Frequency 60 Hz
60 Hz
Más información
MarcaTripp Lite
MPN:SU5KRT3UHVMB
Copyright © 2020-present Comercializadora c&a de america sa de cv