Cyberpower OL6KRTF ups de 6000 va5400 w online doble conversión 200 - 240 vac entrada nema l6-30p 120 salida onda senoidal pura torre o rack 8 ur con 6 tomas 5-20r 2 l6-20r y 1 l6-30r

Precio especial $108,709.00 IVA incluido + Envio $150 MXN
Antes $126,102.00
Disponible 0 Pzas
Agotado
pub
MX0000079821
Precios sujetos a cambios sin previo aviso
Pagos 100% seguros
Entrega Aprox.
Envio Nacional | Condicion: Nuevo


width=600

*Nota: Este equipo debe ser arrancado por un experto de CyberPower para hacer efectiva la garantía. Para más información comunicarse con el departamento de Ingeniería.

Para llevar a cabo el arranque del equipo deberá estar listo en la fecha programada con las siguientes características:

  • Cable 8 AWG del cableado al UPS.
  • Nivel de voltaje de alimentación adecuado de 200-240 VAC.
  • Interruptor de entrada de 60 Ampers (2x30).
  • Sistema de aterrizaje aislado bien referenciado a tierra.

Aplicaciones:

Garantiza protección de respaldo de energía para equipos de TI, servidores, estaciones de trabajo, NAS / dispositivos de almacenamiento, dispositivos de telecomunicaciones, dispositivos de red, sistemas de seguridad / emergencia y sistemas de vigilancia. El UPS adopta una topología de doble conversión para proporcionar potencia de salida de alta calidad con ECO adicional Modo para ahorrar energía y ahorrar en costos de energía.

Este UPS compatible con generador incluye paquetes de baterías intercambiables en caliente para mantenimiento sin interrupción de energía y un interruptor de apagado de emergencia (EPO) para permitir a los usuarios apagar el UPS inmediatamente durante una emergencia.

Especificaciones técnicas:   

  • Voltaje de entrada: 200 - 240 Vac
  • Frecuencia de entrada: 40 - 70 Hz
  • Tipo de enchufe de entrada: NEMA L6-30P/
  • Longitud del cable: 180 cm
  • Salida VA: 6,000
  • Salida Watts: 5,400
  • Baterías: 20 x 12V/7Ah
  • Factor de Potencia: 0.9
  • Tiempo de respaldo con carga completa (5,400 W): 5.4 Minutos
  • Tiempo de respaldo con media carga (2700 W): 15 Minutos
  • Voltaje en Batería: 120 Vac; 200, 208, 220, 230, 240 Vac (Configurable) ±2%
  • Total de tomas de salida: 10
  • Tipo de tomas: NEMA L6-20R (2) /, NEMA L6-30R (1)/, NEMA 5-20R (6),  Hardwire Terminal Block (1)
  • Protección de picos: grado de red
  • Administración Remota SNMP / HTTP: RMCARD205 (Opcional)
  • Módulo de Baterías Extendidas: BP240VL3U01 o BP240V30ART3U
  • Indicadores: Pantalla LCD de lectura
  • Tamaño en Rack: 8U
  • Dimensiones: 433 x 355.6 x 660 mm (Ancho x Alto x Profundidad)
  • Peso: 143.60kg.
  • 3 años de garantía (incluye batería)

 

Description

The CyberPower Smart App Online OL6KRTF is a combined 8U with a 6U rack/tower double-conversion UPS and a 2U step-down transformer to support 120 V and 200-240 V output requirements. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. Generator-compatible, the OL6KRTF delivers consistent output power with zero transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The OL6KRTF features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable) and it has a RMCARD205 pre-installed network card. Smart Battery Management charging technology increases battery life by up to 50%. Fast Charge Technology helps replenish battery charge from 0-90% in four hours regardless of number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation. This UPS can use the BP240V30ART3U or BP240VL3U01 Extended Battery Module for more runtime. The OL6KRTF comes with a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee. Double-Conversion Topology Provides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment. Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies. Step-down Transformer Converts 208V input voltage originating from utility power, a UPS, or a generator to 120V output. The included 6-foot cord (NEMA L6-30P plug to ROJ) connects the transformer to input power. Over temperature protection safeguards it from damage if the internal heat exceeds safe operating parameters. Removable LCD Control Panel Panel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, users can scroll through multiple UPS status readings and run select UPS diagnostic tests. Multiple Language Options The LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries. Extended Battery Module (EBM) Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain. Fast Charge Technology Enables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in four hours. This is possible thanks to the built-in charger in each EBM. Smart Battery Management (SBM) Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained. GreenPower UPS™ ECO Mode Improves UPS efficiency up to 96% to reduce electrical and cooling costs. Hot-Swappable Batteries Eliminate downtime related to UPS maintenance for continuous power availability. Generator Compatible Mode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set. Converter Mode Provides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility. Local and Remote Management Monitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. User can also setup email notifications. Rack or Tower Installation All the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost. PowerPanel® Business Edition Software A robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above. Three-Year Warranty CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. Connected Equipment Guarantee CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.
 

Specifications

 

Power
Output frequency 50/60 Hz
Output power factor 0.9
Input power factor 0.99
Output power 5400 W
Input operation voltage (min) 120 V
Input operation voltage (max) 280 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Surge energy rating 2430 J
Crest factor 3:1
Output power capacity 6 kVA
Efficiency (ECO mode) 96%
ECO mode Yes
Input frequency 40 - 70 Hz
Ports & interfaces
Cable length 118.1' (3 m)
Socket circuit breaker Yes
USB port Yes
Serial interface Yes
Serial interface type RS-232
AC outlets quantity 10 AC outlet(s)
AC outlet types NEMA 5–20R,NEMA L6-20R,NEMA L6-30R
Power plug NEMA L6-30P
USB 2.0 ports quantity 1
Serial ports quantity 1
Modem (RJ-11) ports 2
Ethernet LAN (RJ-45) ports 2
USB port type USB Type-B
Performance
Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm
UPS topology Double-conversion (Online)
Waveform Sine
LED indicators Yes
EMI/RFI noise filtering Yes
Noise level 65 dB
Audible alarm(s) Yes
Overload capacity - line mode (1 minute) 125%
Features
Output frequency 50/60 Hz
Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm
UPS topology Double-conversion (Online)
Waveform Sine
Output power factor 0.9
Input power factor 0.99
Output power 5400 W
Input operation voltage (min) 120 V
Input operation voltage (max) 280 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Surge energy rating 2430 J
EMI/RFI noise filtering Yes
Noise level 65 dB
Crest factor 3:1
Audible alarm(s) Yes
Output power capacity 6 kVA
Overload capacity - line mode (1 minute) 125%
Socket circuit breaker Yes
Efficiency (ECO mode) 96%
ECO mode Yes
Input frequency 40 - 70 Hz
Battery
Number of batteries supported 20
Battery voltage 12 V
Battery capacity 7 Ah
Battery technology Sealed Lead Acid (VRLA)
Typical backup time at half load 15 min
Typical backup time at full load 5.4 min
Hot-swap battery Yes
Cold start Yes
Design
Rack capacity 8U
Form factor Rackmount/Tower
LED indicators Yes
Product colour Black
Safety UL 1778 5th Ed., CSA C22.2 NO.107.3-05, FCC 15 A
Display LCD
Cable length 118.1' (3 m)
Housing material Steel
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -20 - 45 °C
Operating relative humidity (H-H) 0 - 90%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 118110.2' (0 - 3000 m)
Non-operating altitude 0 - 590551.2' (0 - 15000 m)
Technical details
Output frequency 50/60 Hz
Sustainability certificates RoHS
Weight & dimensions
Weight 318.3 lbs (144.4 kg)
Width 17' (433 mm)
Height 14' (355.6 mm)
Depth 26' (660 mm)
Package width 23.6' (600 mm)
Package depth 35.4' (900 mm)
Package height 38.1' (968 mm)
Package weight 410.1 lbs (186 kg)
Packaging data
Rack mount kit Yes
Quick installation guide Yes
Cables included Phone (RJ-11), Serial, USB cable
Package width 23.6' (600 mm)
Package depth 35.4' (900 mm)
Package height 38.1' (968 mm)
Package weight 410.1 lbs (186 kg)
Certificates
Safety UL 1778 5th Ed., CSA C22.2 NO.107.3-05, FCC 15 A
Packaging content
Rack mount kit Yes
Quick installation guide Yes
Cables included Phone (RJ-11), Serial, USB cable
Más información
MarcaCyberpower
MPN:OL6KRTF
Copyright © 2020-present Comercializadora c&a de america sa de cv